INDICATION
Treatment
- Tattoo Removal
- Hair Bleaching
- Pigmented Lesions
- Onychomycosis
- Melasma
- Skin Rejuvenation
01
ADVANCED
Q-SWITCHED Nd:YAG
Q-SWITCHED Nd:YAG
As an advanced Q-switched Nd:YAG laser system, CuRAS provides optimal performance for the treatment of tattoos, melasma, non-ablative resurfacing and pigmented lesions. The dual 1064/532nm wavelengths with different handpieces enable practitioners to select a wide range of applications to suit the needs of each patient, thereby increasing treatment efficacy.

1064nm

532nm
MULTIPLE
HANDPIECE TYPES
HANDPIECE TYPES
Zoom
Handpiece
Adjustable from 2 to 10mm in 1mm increments
Main Uses:
ModeQ 1064, Q 532, PTP 1064,
FR 1064, M 1064, A 1064
Indications
Epidermal & dermal pigmentations
Collimated
Handpiece
An 8mm fixed collimated handpiece for soft peeling
Main Uses:
ModeQ 1064, PTP 1064, M 1064
Indications
Normal dermal pigmentations
OPTION
MLA
Handpiece
Up to 74 fractional dots in a 7mm spot size 15 x more energy in each dot
Three distance gauges:
35mm, 25mm & 15mmMain Uses:
ModeQ 1064, Q 532
Indications
Epidermal & dermal pigmentations
OPTION
585 Dye
Handpiece
Spot size:
2mmPulse Energy:
Max. 200mJMain Uses:
ModeQ 585
Indications
Tattoo removal
OPTION
650 Dye
Handpiece
Spot size:
2mmPulse Energy:
Max. 160mJRepetition rate:
1-2HzMain Uses:
ModeQ 650
Indications
Tattoo removal
PREMIUM MODES

- Pigmentation
- Black & Blue Tattoos
- Hair Bleaching
- Toning
- Soft Peeling
- Skin Rejuvenation
- Pigmentation Red Tattoo
- Melasma
- Onychomycosis
Technology
Highlight
Highlight
ENERGY STABILITY Q1064
CuRAS's superior energy stability and perfect beam profile enable stable and effective thermal energy delivery to the target area over a long treatment period, resulting in uniform clinical efficacy by minimizing damage to surrounding tissue.

Fast and Effective
Compared to single pulse energy, PTP mode delivers peak energy in twin pulses, thereby enabling the use of a higher level of energy for effective treatment even with a large spot size. It also facilitates rapid treatment and increased patient comfort.

Top Hat Beam Profile
The uniform ‘top hat’ shape of the beam profile means CuRAS can deliver a uniform and accurate high quality beam to the target area via its compact dual chamber, guaranteeing safety and efficacy.

Easy and Safe
The spot size of the zoom handpiece can be adjusted from 2 to 10mm in 1 mm increments, enabling practitioners to easily select the appropriate spot size for efficient treatment.

Preset Protocol & Storage Mode
The most commonly used protocols are set for beginners, while experts can save over 100 protocols to prepare for treatment more quickly.

Before & After


Before
After


Before
After